Standard, control and qualification serum panels for testing ELISA and quality control of laboratory tests for detection of infectious diseases markers by LLÑ «MedBioAlliance»
| HIV |
Hepatitis Â, C |
Syphilis |
|
Chlamydia |
TORCH -infection |
|
- Shelf life – 24 months
- Serum panels are produced in lyophilized form that allows you to save the recovered serum at 2°C to 8°C for one month at -20°C for 6 months.
|
Catalog ¹ |
Name |
Pack |
|
Ï–001 |
Standard ÀB(-)HIV-ÌBÀ Standard serum panel (SSP) containing no HIV 1,2 antibodies and p24 antigen of HIV-1 Specificity evaluation of test kits for detection of HIV antibodies |
20 vial (-) |
|
Ï–002 |
Standard ÀB(+)HIV-1-ÌBÀ Standard serum panel (SSP) containing HIV-1 antibodies at different concentrations Sensitivity evaluation of test kits for detection of HIV-1 antibodies |
16 vial (+) |
|
Ï–006 |
Control ÀB(+/-)-HIV-1,2-ÌBÀ Control serum panel containing and not containing HIV 1,2 antibodies Testing the work standards of clinical diagnostic laboratories |
8 vial (6+ and 2-) |
|
Ï–003 |
Standard AB(+)HIV-2-ÌBÀ Standard serum panel (SSP) containing HIV-2 antibodies at different concentrations Sensitivity evaluation of test kits for detection of HIV-2 antibodies |
8 vial (+) |
|
Ï–004 |
Standard ÀG(+)HIV-1 ð24-ÌBÀ Standard serum panel (SSP) containing p24 antigen to HIV-1 at different concentrations Sensitivity evaluation of ELISA for detection of p24 antigen of HIV-1 and test systems for simultaneous detection of HIV-1,2 antibodies and HIV-1 antigen |
10 vial (+) |
|
Ï–008/1 Ï–008/2 Ï–008/3 Ï–008/4 |
IL-Ñontrol-ÀB-HIV-1-ÌBÀ Control serum panel containing HIV-1 antibodies Used for inside laboratory quality control of ELISA |
10 vial (+) 15 vial (+) 24 vial (+) 25 vial (+) |
|
Ï–005 |
Q-ÀB-HIV-1-ÌBÀ Qualification serum panel containing HIV-1 antibodies at different concentrations Testing the work standards of clinical diagnostic laboratories and qualification of personnel |
5 vial (4+ and 1-) |
Diagnostics of hepatitis Â
|
Catalog ¹ |
Name |
Pack |
|
Ï–011 |
Control-HÂsAg-ÌBÀ Control serum panel containing and not containing HBsAg Testing the work standards of clinical diagnostic laboratories dealing with serodiagnostics of hepatitis B |
8 vial ( 5+ and 3 – ) |
|
Ï–010 |
Control ÀB-HÂsAg-ÌBÀ Control serum panel containing and not containing antibodies to HBsAg Testing the work standards of clinical diagnostic laboratories |
8 vial ( 5+ and 3-) |
|
Ï–013 |
Q-HÂsAg –ÌBÀ Qualification serum panel containing HBsAg at different concentrations Testing the work standards of clinical diagnostic laboratories |
5 vial (4+ and 1-) |
|
Ï–012/1 Ï–012/2 Ï–012/3 Ï–012/4 |
IL-Control-HÂsAg-ÌBÀ Control serum panel containing HBsAg Used for inside laboratory quality control of ELISA |
10 vial (+) 15 vial (+) 24 vial (+) 25 vial (+) |
Diagnostics of hepatitis Ñ
|
Catalog ¹ |
Name |
Pack |
|
Ï–018 |
Standard ÀB(+/-)VHC-ÌBÀ Standard serum panel (SSP) containing and not containing antibodies to hepatitis C (VHC) Specificity and sensitivity evaluation of test kits for detection of antibodies to hepatitis C |
24 vial (16+ and 8- ) |
|
Ï–020 |
Control ÀB-VHC-ÌBÀ Control serum panel containing and not containing antibodies to hepatitis C (VHC) Testing the work standards of clinical diagnostic laboratories dealing with serodiagnostics of hepatitis C |
8 vial (4 + and 4-) |
|
Ï–019 |
Q-ÀB-VHC-ÌBÀ Qualification serum panel containing antibodies to VHC with different concentration Testing the work standards of clinical diagnostic laboratories and qualification of personnel |
5 vial (4+ and 1-) |
|
Ï–021/1 Ï–021/2 Ï–021/3 Ï–021/4 |
IL-Control-ÀB-VHC-ÌBÀ Control serum panel containing antibodies to hepatitis C (VHC) Used for inside laboratory quality control of ELISA |
10 vial (+) 15 vial (+) 24 vial (+) 25 vial (+) |
Diagnostics of syphilis
|
Catalog ¹ |
Name |
Pack |
|
Ï–024 |
ÀB-T. pallidum-ÌBÀ Control serum panel containing and not containing antibodies to Treponema pallidum Testing the work standards of clinical diagnostic laboratories |
6 vial (2- and 4+) |
|
Ï–025/1 Ï–025/2 Ï–025/3 Ï–025/4 |
IL-Control-ÀB-T.pallidum-ÌBÀ Control serum panel containing antibodies to Treponema pallidum Used for inside laboratory quality control of ELISA |
10 vial (+) 15 vial (+) 24 vial (+) 25 vial (+) |
|
Ï–023 |
Q-ÀB- Ò.pallidum-ÌBÀ Qualification serum panel containing antibodies to Treponema pallidum with different concentration Testing the work standards of clinical diagnostic laboratories and qualification of personnel |
5 vial (4+ and 1-) |
Diagnostics of chlamydia infection
|
Catalog ¹ |
Name |
Pack |
|
Ï–026 |
Standard ÀB-G(+/-)C.trachomatis-ÌBÀ Standard serum panel (SSP) containing and not containing IgG antibodies to Chlamydia trachomatis Specificity and sensitivity evaluation of test kits for detection of IgG to Chlamydiatrachomatis |
36 vial (16+ and 20-) |
|
Ï–028 |
Control ÀB-G-C.trachomatis-ÌBÀ Control serum panel (SSP) containing and not containing IgG antibodies to Chlamydia trachomatis Testing the work standards of clinical diagnostic laboratories |
8 vial (4+ and 4-) |
|
Ï–027 |
Standard ÀB-À(+/-)C.trachomatis-ÌBÀ Standard serum panel (SSP) containing and not containing IgA antibodies to Chlamydia trachomatis Specificity and sensitivity evaluation of test kits for detection of IgA to Chlamydiatrachomatis |
30 vial (12+ and 18- ) |
|
Ï–029 |
Control ÀB-À-C.trachomatis-ÌBÀ Control serum panel (SSP) containing and not containing IgA antibodies to Chlamydia trachomatis Testing the work standards of clinical diagnostic laboratories |
8 vial (4+ and 4-) |
Diagnostics of TORCH - infection
|
Catalog ¹ |
Name |
Pack |
|
Ï–030 |
Standard ÀB-G(+/-)CMV-ÌBÀ Standard serum panel (SSP) containing and not containing IgG antibodies to cytomegalovirus Specificity and sensitivity evaluation of test kits for detection of IgG to cytomegalovirus |
36 vial (20+ and 16-) |
|
Ï–032 |
Standard ÀB-G(+/-)HSV-ÌBÀ Standard serum panel (SSP) containing and not containing IgG antibodies to HSV 1/2 Specificity and sensitivity evaluation of test kits for detection of IgG to HSV 1/2 |
36 vial (20+ and 16-) |
|
Ï–039 |
Standard ÀB-G(+/-)T.gondii -ÌBÀ Standard serum panel (SSP) containing and not containing IgG antibodies to Toxoplasma gondii Specificity and sensitivity evaluation of test kits for detection of IgG to Toxoplasma gondii |
36 vial (20+ and 16-) |